Flare Intelligence
Know the moment a flare goes out.
A thermocouple can say a flare is lit when it isn’t. Flare Intelligence watches every flare on camera around the clock and tells you whether it is lit or out, clean or smoking, with video on every event. On the Alta camera, which locks an OGI sensor and an optical camera to the same view, it also sees the pilot and flags cold venting the moment unburned gas starts going to a dead flare.
What the rules require for flares
OOOOb already lets a video camera replace monthly Method 22 smoke checks, and from January 2027 every flare must be watched for flame at least every five minutes, with an alert to the control room when it goes out.
| Requirement (OOOOb) | What it says | Date |
|---|---|---|
| Visible emissions | No visible emissions for more than 1 minute in any 15. Check monthly with Method 22, or use a video camera that continuously monitors and records the flame instead | In effect now |
| Video camera alternative | At least 720p, 15 frames per second, within 400 m of the flare, with the feed reviewed at least once a day | In effect now |
| Routine flaring of associated gas | Phased out; temporary flaring allowed only in limited cases (EPA guidance, May 1, 2026) | May 7, 2026 |
| Net heating value of flare gas | Continuous monitoring or a sampling demonstration | June 1, 2026 |
| Pilot or combustion flame | Monitored at least every 5 minutes; alert sent to the nearest control room whenever the flame is unlit | January 22, 2027 |
Why thermocouples and drive-bys miss it
A burning flare is doing its job. The failure is an unlit flare venting raw gas, and today most operators find out late.
- The thermocouple lies. A heat sensor on the stack can read “lit” after the flame is out, or “out” while it burns fine and a truck rolls for nothing.
- The drive-by is a snapshot. A flare that goes out at 2 a.m. vents until someone drives past.
- Method 22 is a spot check. A monthly 15-minute reading misses what happens the other 43,000 minutes.
That gap is detection lag: the time between a flare going out and a human knowing. It is where venting events, complaints and findings come from.
How Flare Intelligence works
One platform, two tiers. Start on the cameras you already have; move to the Alta camera where you need to see the gas itself.
| Flare Intelligence | Flare Intelligence Plus | |
|---|---|---|
| Camera | Any optical camera you already own | The Alta camera: OGI and optical sensors locked to the same pan, tilt and zoom |
| Flame status | Lit or out, 24/7 | Lit or out, 24/7 |
| Smoke | Smoke detected and graded by color (white, gray, black, brown) | Same |
| Pilot status | — | Pilot lit or out |
| Cold venting | — | Flags unburned gas going to a dead flare the moment it starts |
| False alarms | — | Fewer: methane is invisible to the optical camera, so a plume the optical sees is steam or dust and gets dropped |
| Evidence | Annotated and raw video plus a keyframe on every event | Same, plus OGI imagery |
Moving up to Plus is a camera upgrade, not a new system. Alta is the only camera we know of that puts OGI and optical on one synced view.
What your team gets
- Flare-out, smoking-flare and, on Plus, pilot-loss and cold-vent alerts the moment they happen
- A visual check on the thermocouple you don’t trust, so you know when the sensor, not the flare, is the problem
- Camera health alerts: a bumped or blocked camera flags itself instead of watching empty sky
- Trends by flare, site and equipment maker for root-cause work
- One dashboard for every flare across every facility, on the same Autonomous365 platform as leak and spill detection
Where it fits your compliance program
| Requirement | What Flare Intelligence provides |
|---|---|
| Method 22 / OOOOb visible emissions | Continuous recorded video of the flame with automated smoke detection, built for OOOOb’s video-camera alternative to monthly Method 22 checks |
| OOOOb pilot and flame presence | Independent, continuous visual confirmation of flame and, on Plus, pilot status, with alerts to your control room |
| State and local flare rules | A time-stamped visual record of flare operation |
| Cold-vent evidence (Plus) | OGI imagery showing when a flare stopped burning and vented unburned gas |
Proof
At sites CleanConnect monitors, annual fire and flare incidents dropped 63%.
- At scale (as of May 2026): 7 million+ true positive detections, 7,350+ active AI models, 4,750+ live camera streams.
- In the field: a gas leak that sparked a fire at a remote facility was caught early, averting a broader fire and months of downtime. Estimated alert value: $5M+.
- Same platform, regulator-tested: CleanConnect’s LeakFinder is EPA-approved for OOOOb leak screening at component level (OOOOb leak monitoring), with state approvals in Colorado, New Mexico, Pennsylvania and New York (approvals).
Customers include Chevron and large independents across the major U.S. basins.
Frequently asked questions
How do I know when my flare goes out?
Put it on camera. Flare Intelligence watches each flare 24/7 and sends an alert the moment it goes out, with video of the event. With the Alta camera it also sees the pilot and flags cold venting.
Can I trust my flare thermocouple?
Not on its own. Thermocouples can read lit after the flame is out, or out while it burns. Flare Intelligence gives you an independent visual check and flags when the sensor, not the flare, is the problem.
Can a camera replace Method 22 under OOOOb?
Yes. OOOOb lets operators use a video camera that continuously monitors and records the flare instead of monthly Method 22 observations, as long as it records at 720p or better, 15 frames per second, from within 400 meters, and the feed is reviewed daily. Flare Intelligence adds automated smoke detection on top of that record.
What does OOOOb require for flare pilots?
From January 22, 2027, the pilot or combustion flame must be monitored at least every five minutes, with an alert to the nearest control room whenever it is unlit.
What is cold venting?
Cold venting is when a flare’s flame and pilot are out and gas still flows to it, so methane goes to the atmosphere unburned. Flare Intelligence Plus uses the Alta camera’s OGI sensor to see that gas and flag it as it starts.
Do I need new cameras?
No for the standard tier: it runs on optical cameras you already own. The Plus tier uses the Alta camera, which adds an OGI sensor locked to the same view as the optical camera.
What is the Alta camera?
A fixed camera with an OGI sensor and an optical camera locked to the same pan, tilt and zoom, so the visible flame and the invisible gas are captured from the same angle at the same moment. We know of no other camera that does this. It hooks up with two weatherproof cables.
What does Flare Intelligence cost?
Pricing depends on flare count and tier. A 30-minute online briefing scopes it.
If a flare went out at 2 a.m. tonight, when would you know?
In 30 minutes we’ll walk your flare count, your cameras and the rules that apply, and show which tier fits.
Sources: 40 CFR 60.5417b; IOGCC OOOOb/c rule status, May 2026; EPA flaring guidance, May 2026. Flare Intelligence supports your compliance workflow and does not replace your regulatory determinations. Regulatory dates as of October 2026.