EPA OOOOb & OOOOc compliance

Continuous OGI that meets EPA’s OOOOb requirements

Yes, you can replace walking every site with a handheld OGI camera. CleanConnect’s LeakFinder System puts a permanently mounted OGI camera and on-site AI on the pad, watching for methane 24/7. It meets EPA’s OOOOb and OOOOc requirements: EPA approved it in May 2025 as an alternative test method for periodic screening. Your existing cameras add flare, spill and fire detection on the same alert feed.

It’s the only autonomous OGI approved at component level, EPA’s finest resolution: a fixed camera that screens 24/7 with no drone, no pilot and no technician on site. An alert points to the leaking component, within about half a meter. Fix it remotely within the 7-day screening window and LeakFinder verifies the repair on its next pass, so nobody drives out.

Request a Briefing

What OOOOb requires now

Fugitive emissions monitoring at well sites and compressor stations is in force today; EPA’s 2025 deadline extensions did not touch it. What moved were flare, control device and Super Emitter dates.

RequirementDate in effect
Fugitive emissions monitoring (OGI or Method 21, or an approved advanced-technology alternative)In effect now, not extended
Flare and enclosed combustion net heating value monitoringJune 1, 2026
Initial annual OOOOb reportsNovember 30, 2026
Super Emitter Program, storage vessel limits, zero-emission controllers, combustion device testingJanuary 22, 2027
OOOOc state plans due to EPAJanuary 22, 2027

EPA is reconsidering the Super Emitter Program and several control-device provisions, with a proposal expected in 2026. Operators who build their programs on measured data now are covered whichever way that lands.

The gap between surveys

A handheld OGI survey proves a site was clean on the day the technician was there. A leak that starts the next morning runs until the next visit, and nobody knows.

That gap is detection lag: the time between an event at a remote facility and a human knowing about it. It is where super-emitter events, satellite detections and avoidable product loss come from.

  • Survey day: a technician drives out, walks the pad, finds nothing.
  • Day 2: a valve packing fails. No one is on site.
  • Weeks later: the next survey, a satellite pass, or a neighbor finds it first.

Continuous OGI closes the gap. Instead of a snapshot every quarter, a camera that never leaves the site watches it every hour of every day, and the same system satisfies the EPA screening requirement.

How CleanConnect covers OOOOb

Two layers feed one alert stream in Autonomous365: Minerva with LeakFinder for the EPA-approved methane screening, and your existing cameras for everything else that goes wrong on a pad.

NeedWhat does itHow
OOOOb / OOOOc fugitive emissions screeningLeakFinder on MinervaContinuous OGI: a permanently mounted camera on a gimbal, with AI on the edge flagging plumes 24/7. Meets OOOOb as an EPA-approved alternative test method (5 kg/hr threshold)
Follow-up after a detectionLeakFinder + your crewComponent-level alerts point to the leaking part; fix it remotely within the 7-day window and LeakFinder verifies the repair and closes the ticket, no handheld OGI visit, with images on file
Covers and closed vent systemsLeakFinder on MinervaIncluded in the EPA approval scope
Flare status (unlit or venting)Flare Intelligence on existing cameras or MinervaAlerts the moment a pilot goes out, with event start and stop times
Liquid leaks, fire, tank levels, PPE, securityExisting cameras (RTSP/ONVIF)Every model runs on every stream, around the clock
Records for auditsAutonomous365Timestamped detections, processed OGI imagery and alert history kept for regulators and third-party audits

No new cameras are needed for the visual layer. Minerva goes where the methane screening is required or connectivity is thin.

Proof

LeakFinder holds an EPA alternative test method approval and four state approvals, backed by 7 million+ true positive detections in production.

AgencyWhat was approved
U.S. EPA (May 2025, MATM-011)LeakFinder System as an alternative test method for OOOOb/OOOOc periodic screening at component-level resolution, also usable in place of OOOOa fugitive monitoring (EPA approval letter)
Colorado CDPHE (Dec 2023)Met Colorado’s Alternative Approved Instrument Monitoring Method requirements
New Mexico NMED (Jan 2026)Conditional approval as a pre-approved alternative monitoring technology
Pennsylvania DEP (Jan 2026)Approved alternative monitoring technology for LDAR programs
New York DEC (Feb 2026)Alternative leak detection technology under 6 NYCRR Part 203

Full list: cleanconnect.ai/approvals.

At scale (as of May 2026): 7 million+ true positive detections, 7,350+ active AI models, 4,750+ live camera streams. Annual gas leak incidents down 50% at monitored sites.

  • A super-emitter release outside the exclusion zone was stopped before prolonged leakage, avoiding public satellite detection. Estimated alert value: $25K+.
  • A gas leak that started a fire at a remote facility was detected early, averting a broader fire and months of downtime. Estimated alert value: $5M+.

Customers include Chevron and large independents across the major U.S. basins.

Frequently asked questions

Is there an EPA-approved alternative to handheld OGI surveys for OOOOb?

Yes. CleanConnect’s LeakFinder System meets EPA’s OOOOb and OOOOc requirements. EPA approved it in May 2025 (MATM-011) as an alternative test method for periodic screening under 40 CFR 60.5398b(b).

Is LeakFinder continuous monitoring?

Yes, in practice: it is continuous OGI, a fixed camera screening the site around the clock. EPA’s “continuous monitoring” category was written with fenceline sensors in mind, before continuous OGI existed, so LeakFinder is approved under the periodic screening pathway. You get continuous coverage and a compliant, EPA-approved method in one system.

What does component-level mean, and why does it matter?

OOOOb sorts screening methods by how precisely they locate a leak: facility level, area level or component level. Component level is the finest, identifying a leak within about half a meter of the source. That precision is what lets most leaks be found, fixed and verified without sending a crew to survey the site. LeakFinder is approved at component level wherever the camera has a direct line of sight.

Do I have to send an OGI crew to verify every leak?

Not when the fix happens inside the screening window. LeakFinder screens each site autonomously over a 7-day window. If your team repairs a leak remotely within that window, LeakFinder checks it again on its next pass, confirms it’s no longer leaking and closes the repair ticket automatically. A crew goes out only if the source can’t be pinpointed within the 7-day window. And the window is hard to miss: EPA requires 15 valid passes in 7 days, about 10% of what LeakFinder runs.

How is LeakFinder different from drones and handheld OGI?

Drone and handheld methods are flown or carried on a schedule and need a pilot or technician for every survey. LeakFinder is a permanently mounted OGI camera with AI that screens the site around the clock on its own, and it’s approved at component level.

What is LeakFinder?

LeakFinder is CleanConnect’s leak detection system. A permanently mounted optical gas imaging camera on a gimbal, paired with AI running on the Minerva edge computer, detects methane plumes and sends results to the Autonomous365 dashboard.

What happens when LeakFinder detects a leak?

Your team gets an alert pointing to the leaking component, with OGI imagery. Fix it, and LeakFinder confirms the repair on its next pass and closes the ticket. A crew goes out only if the source can’t be pinpointed within the 7-day screening window.

Can my existing security cameras detect methane?

No. Standard cameras cannot see methane; that takes an OGI camera like the one in Minerva. Your existing cameras still add 24/7 detection of unlit flares, liquid leaks, fire, tank levels and site security.

Did EPA’s 2025 extension delay fugitive emissions monitoring?

No. Fugitive emissions requirements at well sites and compressor stations stayed in place. The extensions moved flare monitoring, control device and Super Emitter Program dates.

Which states have approved LeakFinder?

Colorado, New Mexico (conditional), Pennsylvania and New York, in addition to EPA.

What does CleanConnect cost?

Pricing depends on site count and coverage. A 30-minute online briefing scopes it; an in-person Optimization Workshop then builds the ROI on your own well count and routes.

How long does a leak run at your sites before anyone knows?

In 30 minutes we’ll map your OOOOb obligations to what LeakFinder and your existing cameras can cover, site by site.

Request a Briefing

Sources: EPA final rule on deadline extensions; IOGCC OOOOb/c rule status, May 2026; EPA approval letter, MATM-011. Regulatory dates as of October 2026.

Scroll to Top
We use cookies to enhance your experience, analyze site traffic and deliver personalized content.
Read our Cookies Policy